P40U-F / P40U-IF I&O Manual
IM101220
RD: JAN 2014
RL: 4A
INSTALLATION / OWNER’S MANUAL
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation and operating and maintenance instruc-
tions thoroughly before installing or servicing this equipment.
SAFETY ALERT:
This heater must be installed and serviced only by a trained gas service techni-
cian. Failure to comply could result in personal injury, death, fire and/or property
damage.
Do not store or use gasoline or other flammable vapours and liquids in the
vicinity of this or any other gas fired appliance.
IF YOU SMELL GAS:
 Extinguish any open flame
 Do not attempt to light this or any other appliance
 Don’t touch any electrical switch, or telephone
 Immediately call your gas supplier from a neighbor’s phone
 Follow any and all instruction from your gas supplier
 If your gas supplier is not available, call the fire department
WARNING
FIELD CONVERTIBILITY:
This appliance is field con-
vertible to LP gas using an
optional kit supplied by the
manufacturer
Keep this manual in a secure place .
Record for future reference:
Model #:
Serial #:
(located on heater rating label)
Models
P40U, P40U-F,
P40U-P, P40U-W
LOW INTENSITY TUBE TYPE
INFRA RED HEATERS
&
Models
P40U-I, P40U-I-F,
P40U-IP, P40U-IW
LOW INTENSITY TUBE TYPE
INFRA RED HEATERS
Vue de la page 0
1 2 3 4 5 6 ... 50 51

Résumé du contenu

Page 1 - P40U-IP, P40U-IW

P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A INSTALLATION / OWNER’S MANUAL Improper installation, adjustment, alteration, service

Page 2

10 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A WARNING Improper installation, adjustment, alteration, service or maintenance can ca

Page 3 - TABLE OF CONTENTS

11 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Proximity of lights, sprinkler heads, overhead doors, storage areas, gas and electri

Page 4

12 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A IMPORTANT: Single or multiple heater placement must be such that continuous operatio

Page 5

13 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 2. Connect to the structure using mechanically sound means to support the weight. E

Page 6 - Clearance to combustibles

14 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A For 30° angle mount: Remove burner (4 bolts + spark wire); Install the tube system;

Page 7 - / P40U-IW

15 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A FIGURE 6 P40U MINIMUM CLEARANCES TO COMBUSTIBLES It is the installer’s responsibil

Page 8

16 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 8-A SEISMIC RESTRAINT - LATERAL AND LONGITUDINAL PLANES In areas prone to earthqua

Page 9

17 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A WARNING 9. FLUE VENTING Inadequate venting of a heater may result in asphyxiati

Page 10 - WARNING

18 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A HORIZONTAL VENT THROUGH A SIDE WALL:  Maximum allowable flue vent length is equiva

Page 11 - 24” (61 cm)

19 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A  Termination Cap Options:  Use the approved 4" (10 cm) (JA-0528-XX) or 6&q

Page 12 - RD: JAN 2014

2 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A NOTICE: This manual is current for this product. Occasional revision of the product

Page 13

20 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A VERTICAL VENT THROUGH THE ROOF: It is the sole responsibility of the installer to ad

Page 14

21 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Optional 4 inch intake terminals are available for this heater:  Part number: JS-0

Page 15

22 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A DO NOT use pressure greater than 1/2 psig to pressure check the heater. During any p

Page 16

23 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 12. GAS CONVERSION WARNING: Gas conversion must only be performed by a trained gas

Page 17

24 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 13. ELECTRICAL AND THERMOSTAT WIRING (WIRING DIAGRAMS PAGE 26 & 27) The hea

Page 18

25 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 18. FENWAL DSI: WIRING DIAGRAM: 24V OR 120 VOLT THERMOSTAT OPERATION SINGLE HEATER

Page 19

26 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 18. MULTIPLE TUBE HEATERS per THERMOSTAT (ALL DSI TYPES) Each tube heater requires

Page 20

27 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 19. FENWAL DSI: SEQUENCE OF OPERATION / FLAME RECOVERY / SAFETY LOCKOUT Power Up / S

Page 21

28 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Flame Fault If at any time the main valve fails to close completely and maintains a

Page 22

29 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A SERVICE CHECKS Flame current passes through the flame from the sensor to ground. Th

Page 23

3 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A TABLE OF CONTENTS IMPORTANT INFORMATION - READ FIRST APPLICATION...

Page 24

30 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Each tube heater requires 120V, 60 HZ electrical power sized for 145VA. The heate

Page 25

31 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 21. P40U-P (-IP), P40U-W (-IW) SEQUENCE OF OPERATION GASLITER 50N (DSI) The Gasliter

Page 26

32 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 22. IGNITION CONTROL: MODELS P40U-P, -W (-IP, -IW) - GASLITER MICRO 50N The MICRO 5

Page 27 - THREE TRIAL MODEL)

33 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Loss of Flame - Spark Restoration Retrial If there is a loss of flame during the run

Page 28

34 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A USE THE BLACK BARS BELOW AS A GUIDE FOR AD-JUSTMENT. USE THE BARS THAT COINCIDE

Page 29 - SERVICE CHECKS

35 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 24. TROUBLESHOOTING GUIDE — HEATER OPERATION — FENWAL DSI Improper adjustment, alte

Page 30

36 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A MAIN BURNER LIGHTS SYSTEM RUNS UNTIL CALL FOR HEAT ENDS CALL FOR HEAT ENDS: SYSTEM

Page 31

37 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 25. START-UP / COMMISSIONING SHEET COMMISSIO

Page 32

38 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A TYPE OF GAS: NG LP DOES BUILDING HAVE A NEGATIVE CONDITION: YES NOIF THIS IS A H

Page 33

39 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Assembled System:  Weight: 86 pounds (39 kg)  Dimensions: 119.5” L x 20” W x 12”

Page 34 - 3/16” 1/4”

4 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A INSPECT PRODUCT UPON RECEIPT Inspect the carton and heater for concealed damage. Note

Page 35

40 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A ORIFICE CHART - ALTITUDE CONVERSION MODEL NO FOR USE AT ALTITUDES ABOVE (FEET) Gas

Page 36

41 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 28. OPTIONAL ACCESSORIES Flue Vent Terminal 4” wall horizontal 6” wall horizontal

Page 37

42 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A #2 Lion Chain (115 lb work load) - 200 ft roll Safety Snap Hooks - 2” - pkg of 25

Page 38

43 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A JS-0502-UR-GK PROTECTIVE GUARD SCREEN OPTION – Zinc Plated; Two Piece Kit – Re

Page 39

44 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Fig.5 Fig. 6 STEP 4: On the second side of the reflector, first Insert a guard pin

Page 40 - Supplied

45 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 29. REPLACEMENT PARTS LIST P40U BURNER # PART DESCRIPTION PART # PART DESCRIPTION PR

Page 41 - 28. OPTIONAL ACCESSORIES

46 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A # PART DESCRIPTION PART # PART DESCRIPTION PRIMARY SUPPLEMENT 23 INDICATOR LAMPS JW

Page 42

47 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 30 TUBE FASTENING BRACKET JS-0502-UV Positions tube in hanger / reflector system 3

Page 43

48 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A HONEYWELL S87-J WIRING DIAGRAM P40U, P40U-I : 24V OR 120 VOLT THERMOSTAT SINGLE HE

Page 44

49 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A HONEYWELL S87J: MODELS P40U, P40U-I SEQUENCE OF OPERATION The S87 ignition control

Page 45 - P40U BURNER

5 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Heater Expansion It is a normal condition that during heat-up and cool-down a tube h

Page 46 - P40U-IW

50 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A LOW/ UNSTEADY FLAME CURRENT If the current to the S87 flame circuit is less than 1.5

Page 47

51 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A LIMITED WARRANTY CERTIFICATE FOR GAS-FIRED INFRA-RED LOW INTENSITY TUBE HEATERS: P40

Page 48

6 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A Clearance to combustibles Location of flammable or explosive objects, liquids or vap

Page 49

7 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A FIGURE 1 MINIMUM CLEARANCES TO COMBUSTIBLES* - Table 1 lists values *The clearance t

Page 50

8 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A VENT END CLEARANCE: Clearances from the vent pipe are determined by local or national

Page 51 - LIMITED WARRANTY CERTIFICATE

9 P40U-F / P40U-IF I&O Manual IM101220 RD: JAN 2014 RL: 4A 2. INSTALLATION IN COMMERCIAL AIRCRAFT HANGARS Low intensity radiant tube heaters ar

Commentaires sur ces manuels

Pas de commentaire