Vue de la page 24
SP-MSJR-BX-08C
STR-JZ Manual
RD: NOV 2006
RL: 8C
BA
Page 21
15. LIGHTING INSTRUCTIONS
Refer to the lighting instructions on the outside
cover of the burner housing. Again, if the unit
locks out on safety, main power to the unit must
be manually interrupted for a 30 second reset
period before the heater can be restarted.
NOTE:
On initial installation, the unit may
lock out on safety owing to the
length of time required to bleed air
from the gas piping system.
16. RECOMMENDED MAINTENANCE
1. Prior to each heating season a qualified service agency shall thoroughly inspect the heater, gas and
electrical supplies, thermostat connections, the venting and combustion air duct. Worn parts shall be
repaired or replaced as required.
2. Check the inlet air opening and the blower periodically, cleaning off any lint or foreign matter, as it
is important that the flow of combustion and ventilation air must not be obstructed.
3. Lubricate Blower motor, by adding several drops of oil to oil ports located on the left hand side of
the motor.
4. Inspect and ensure that the flame inspection port is clean and free of defects.
THE SCHWANK TUBE HEATER BURNER IS COMPLETELY FACTORY ASSEMBLED AND
TESTED. ANY ALTERATION VOIDS THE CSA CERTIFICATION AND MANUFACTURER’S
WARRANTY. FOR ADDITIONAL INFORMATION, CONTACT YOUR LOCAL DISTRIBUTOR